| Figure 1. Photograph from Chapter 5 of FEMA's Building Performance Assessment Report. |
I used landmarks in this photo to make several approximate measurements of the frontier of the dust cloud. The following table lists some of them. Measurements are in feet. The first column lists heights above the street, and the second lists distances from the vertical axis of the North Tower.
| label | height | distance | description |
|---|---|---|---|
| 3 | 230 | 1011 | west corner of 45 Park Place |
| 5 | 228 | 729 | top of south corner of building with stepped roof |
| 6 | 204 | 658 | east corner of Building 7, 30 stories below top |
| 7 | 600 | 776 | upwell towering over southeast end of Post Office |
| 8 | 700 | ? | upwell slightly higher than the top of Building 7 |
| 11 | 190 | 870 | top of west corner of 22 Cortland St tower |
| 12 | 508 | 588 | 8 stories below top of face of WFC 3 |
| 13 | 498 | 517 | 3 stories below top of upper face of WFC 2 |
To approximate the volume I used a cylinder, coaxial with the vertical axis of the North Tower, with a radius of 800 feet, and a height of 200 feet. All the above reference points lie outside of this volume. Although the cylinder does not lie entirely within the dust cloud, there are large parts of the cloud outside of it, such as the 700 foot high upwelling column south of Building 7. The cylinder has a volume of:
pi * (800 feet)^2 * 200 feet = 402,000,000 feet^3.
I subtract about a quarter for volume occupied by other buildings, giving 300,000,000 feet^3.
To accurately answer question 2 would require detailed knowledge of the fluid dynamics involved. However it does appear that for at least a minute, the dust cloud behaved as a separate fluid from the ambient air, maintaining a distinct boundary. There are several pieces of evidence that support this:
Instinctively I lifted the camera up, and something took over that probably saved my life. And that was [an urge] to run rather than take pictures. I got down to the end of the block and turned the corner when a wave-- a hot, solid, black wave of heat threw me down the block. It literally picked me up off my feet and I wound up about a block away.
Initially the dust clouds must have been much heavier than air, given the mass of the concrete they carried and the distances they transported it. As time went on the cloud became more diffuse, but all of the photographs that can be verified as being within the first minute show opaque clouds with distinct boundaries, indicating the dominant mode of growth was expansion, not mixing or diffusion. It seems reasonable to assume that mixing with ambient air did not account for a significant fraction of the expansion in the volume of the dust cloud by 30 seconds of the start of the North Tower collapse. Nevertheless, I reduce the estimate of the dust cloud volume of building origin to 200,000,000 feet^3, imagining that a third of the growth may have been due to assimilation of ambient air.
The answer to question 3 is easy. The volume of a tower, with it's 207 foot width and 1368 foot height, is:
1368 feet * 207 feet * 207 feet = 58,617,432 feet^3.
So the ratio of the expanded gasses and suspended materials from the tower to the original volume of the tower is:
200,000,000 feet^3 / 58,617,432 feet^3 = 3.41.
Above I identified two energy sinks that could have driven expansion of the dust cloud: thermodynamic expansion of gases, and vaporization of liquids and solids. Since most constituents and contents of the building other than water would require very high temperatures to vaporize, I consider only the vaporization of water in evaluating the second sink.
It is clearly not possible to determine with any precision the relative contributions of these two sinks to the expansion of the dust cloud. If the cloud remained uniform in temperature and density for the first 30 seconds, then the expansion would consist of three distinct phases:
Since such uniform conditions were not present, I will first treat the two energy sinks separately, and will compute the energy requirements for each if it alone were responsible for the expansion.
The ideal gas law can be used to compute a lower bound for the amount of heat energy required to induce the observed expansion of the dust cloud, assuming that the expansion was entirely due to thermodynamic expansion. That law states that the product of the volume and pressure of a parcel of a gas is proportional to absolute temperature. It is written PV = nRT, where:
P = pressure V = volume T = absolute temperature n = molar quantity R = constant
Absolute temperature is expressed in Kelvin (K), which is Celsius + 273. Applied to the tower collapse, the equation holds that the ratio of volumes of gasses from the building before and after expansion is roughly equal to the ratio of temperatures of the gasses before and after heating. That allows us to compute the minimum energy needed to achieve a given expansion ratio knowing only the thermal mass of the gasses and their average temperature before the collapse.
I say that the ideal gas law allows the computation of only the lower bound of the required energy input due to the following four factors.
In this paper I examine only the fourth factor. Before considering its effect on energy requirements, I first consider the energy requirements of heating only the gasses in the clouds to the level needed to achieve the observed expansion.
According to the ideal gas law, expanding the gasses 3.4-fold requires raising their absolute temperature by the same ratio. If we assume the tower was at 300 degrees K before the collapse, then the target temperature would be 1020 degrees K, an increase of 720 degrees. Given a density of 36 g/foot^3 for air, the tower held about 2,000,000,000 g of air. Air has a specific heat of 0.24 (relative to 1 for water), so one calorie will raise one g of air 1 / 0.24 = 4.16 degrees. To raise 2,000,000,000 g by 720 degrees requires:
2,000,000,000 g * 720 degrees * 0.24 = 345,600,000,000 calories
= 399,500 KWH
To evaluate the energy requirements of the fourth factor, it is necessary to consider the composition of the dust cloud. The cloud was a suspension of fine particles of concrete and other solids in gasses consisting mostly of air. Since concrete was the dominant solid, I will ignore the others, which included glass, gypsum, asbestos, and various hydrocarbons. The small size of the particles, being in the 10-60 micron range, would assure rapid equalization between their temperature and that of the embedding air. Therefore any heat source acting to raise the temperature of the air would have to raise the temperature of the suspended concrete by the same amount. Assuming all 90,000,000,000 g of concrete was raised 720 degrees (300 K to 1020 K), the necessary heat, given a specific heat of concrete of 0.15 is:
90,000,000,000 g * 720 degrees * 0.15 = 9,720,000,000,000 calories
= 11,300,000 KWH.
If we assume that the water vaporization sink absorbed all available energy once temperatures reached water's boiling point, we can compute the size of the heat sink of thermodynamic expansion that was in play up to 100 C, or 737 K:
2,000,000,000 g * 73 degrees * 0.24 = 35,040,000,000 calories
= 40,744 KWH
The associated sink of heating the suspended solids to this temperature would be:
90,000,000,000 g * 73 degrees * 0.15 = 985,500,000,000 calories
= 1,145,000 KWH.
At 100 C at sea-level, water expands by a factor of 1680 when converted to steam. Hence it is reasonable to expect that water in the building accounted for a significant part of the expansion. How much energy would be required to expand the volume of the cloud by the 3.41 ratio if water vaporization were entirely responsible for the expansion? Since water vaporization involves the introduction of volumes steam from comparatively negligible volumes of water, I assume that all the incremental volume was occupied by steam. The estimated 3.41 expansion ratio means that the incremental volume was:
200,000,000 feet^3 - 58,617,000 feet^3 = 141,383,000 feet^3
= 4,003,542,000 liters
Given the 1680 to 1 ratio between the volume steam and water, 2,383,000 liters of water would have been required. The heat of vaporization of water is 540 calories/gram at 100 C. Therefore the heat energy required to produce the expansion is:
2,383,000,000 g * 540 = 1,286,820,000,000 calories
= 1,496,000 KWH
Was there enough water in the building for this sink to be anywhere near this large? That is a matter of great uncertainty. Even well-cured concrete has a significant moisture content. Assuming that the estimated 90,000 tons of concrete in the tower was 1 percent water by weight, that would have provided 900 tons of water or about 900,000 liters -- well short of the 2,383,000 liter estimate above. However, there is a large amount of uncertainty in the water content of the concrete, which, like the rest of the remains of the disaster was apparently disposed of with little or no examination. Moreover there were other sources of water in the building, such as the plumbing system, which could have accounted for tens of thousands of liters, and, gruesomely, people. The thousand victims never identified could have accounted for about 30,000 liters of water.
Both thermodynamic expansion and water vaporization have the capacity to produce vast expansion in gas volume given sufficient heat. Two major difference in the features of these sinks may help in understanding the relative contributions of each. First, thermodynamic expansion to the observed ratio requires very high temperatures, whereas vaporization-driven expansion occurs at a constant temperature of 100 C. Second, vaporization-driven expansion would be limited by the available supply of water.
If all the expansion was due to thermodynamic expansion, it would require that the dust cloud was heated to an average temperature of about 1020 K. Certainly the temperatures of the cloud near the ground were no-where near that high. Eyewitness reports show that the cloud's ground-level temperatures more than a few hundred feet away from its center were humanly survivable. Most of these reports are from the South Tower collapse, and it is unclear how similar the dust cloud temperatures following the two collapses were. Although serious fires raged in Buildings 4, 5, and 6, other nearby buildings that suffered extensive window breakage from the tower collapses, such as the Banker's Trust Building, and Word Financial Center Buildings 1, 2, and 3, did not experience fires. Digital photographs and videos show a bright afterglow with a locus near the center of the cloud, commencing around 17 seconds after the onset of the North Tower's collapse. Once the afterglow started, the cloud developed large upwelling columns towering to over 600 feet, and the previously gray cloud appeared to glow with a reddish hue. This suggests that at lest the upper and central regions of the North Tower cloud reached very high temperatures, but the evidence is insufficient to draw even general quantitative conclusions about the ranges and distributions of temperatures.
If enough water was present for vaporization to drive most of the expansion, temperatures in much of the cloud would have remained around 100 C until most of the water had vaporized. Thermodynamic expansion would occur in regions with liquid phase water until 100 C was reached, and again after the water was vaporized.
To the extent that thermodynamic expansion was the dominant factor driving the expansion, the distribution of concrete dust in the cloud, and its relationship to the temperature distribution in the cloud, would greatly affect the total energy requirements. Less energy would be required if the hotter portions of the cloud had a lower density of dust. The density was probably greater toward the central portions of the cloud, which also seem to have experienced the most heating. On the other hand, much of the dust may have settled out by the 30 second mark. The violent churning of the cloud, and the opaque appearance of its frontier, suggest that most of the dust had not settled that early.
The dominant energy source assumed to be in play during the leveling of each of the Twin Towers was the gravitational energy due to its elevated mass, whereas the energy sinks included the pulverization of it's concrete, the vaporization of water, and the heating of the concrete and air in the ensuing dust cloud. Estimates for these energies are:
| energy, KWH | source or sink |
|---|---|
| + 111,000 | falling of mass (1.97e11 g falling average of 207 m) |
| - 135,000 | crushing of concrete (9e10 g to 60 micron powder) |
| ignoring water vaporization | |
| - 400,000 | heating of gasses (2e9 g air from 300 to 1020 K) |
| - 11,300,000 | heating of suspended concrete (9e10 g from 300 to 1020 K) |
| assuming water vaporization sink was not supply-limited | |
| - 1,496,000 | vaporization of water (2.38e9 g water) |
| - 41,000 | heating of gasses (2e9 g air from 300 to 373 K) |
| - 1,145,000 | heating of suspended concrete (9e10 g from 300 to 373 K) |
The imbalance between sources and sinks is striking, no matter the relative shares of the thermodynamic and water vaporization sinks in accounting for the expansion. Moreover, it is very difficult to imagine how the gravitational energy released by falling mass could have contributed much to any of the sinks, since the vast majority of the tower's mass landed outside its footprint. The quantity for the crushing of concrete appears to be conservative since some reports indicate the average particle size was closer to 10 microns. The quantity for the heating of suspended concrete has a large amount of uncertainty, but the energy imbalances remain huge even when it is ignored entirely. All of these energy sink estimates are conservative in several respects.
The calculation also ignores the role the mass of the suspended materials in impeding the expansion of cloud and thereby increasing the required energy.
The amount of energy required to expand the North Tower's dust cloud was many times the entire potential energy of the tower's elevated mass due to gravity. The over 10-fold disparity between the most conservative estimate and the gravitational energy is not easily dismissed as reflecting uncertainties in quantitative assessments.